BACKGROUND: Radial artery cannulation is extremely challenging in neonatal patients. Herein, we compared the success rate of the modified dynamic needle tip positioning short-axis, out-of-plane, ultrasound-guided technique with that of the traditional palpation technique in neonatal radial artery cannulation. METHODS: Sixty term neonates undergoing major abdominal surgery were randomized into the ultrasound or palpation group via the sealed-envelope method. The ultrasound group underwent radial artery cannulation using an ultrasonic apparatus, while traditional palpation of arterial pulsation was used in the palpation group. The arterial diameter and depth were measured on ultrasound before the puncture. We recorded age, weight, sex, and other background characteristics. The primary outcomes included the first-attempt, total success rates, and the total puncture procedure duration. Secondary outcomes included the incidence of complications (hematoma and thrombosis). Data were compared between the 2 groups. RESULTS: Sixty term neonates were enrolled in the study. The success rates of the first attempt in the ultrasound and palpation groups were 40% (n = 30) and 10% (n = 30), respectively (P = .007; relative risk, 4.0; 95% confidence interval, 1.3–12.8). The total success rate was 96.7% in the ultrasound group and 60.0% in the palpation group (P = .001; relative risk, 1.61; 95% confidence interval, 1.19–2.17). The average time to accomplish radial artery cannulation in the ultrasound and palpation groups was 91.4 ± 55.4 and 284.7 ± 153.6 seconds, respectively (P
from Anaesthesiology via xlomafota13 on Inoreader https://ift.tt/2KLu0vb
via IFTTT
Εγγραφή σε:
Σχόλια ανάρτησης (Atom)
Δεν υπάρχουν σχόλια:
Δημοσίευση σχολίου
Σημείωση: Μόνο ένα μέλος αυτού του ιστολογίου μπορεί να αναρτήσει σχόλιο.