Publication date: Available online 31 July 2017
Source:Clinical Neurophysiology
Author(s): Chao-Jung Hsu, Janis Kim, Rongnian Tang, Elliot J. Roth, William Z. Rymer, Ming Wu
ObjectiveTo determine whether applying a mediolateral corrective force to the pelvis during treadmill walking would enhance muscle activity of the paretic leg and improve gait symmetry in individuals with post-stroke hemiparesisMethodsFifteen subjects with post-stroke hemiparesis participated in this study.A customized cable-driven robotic system based over a treadmill generated a mediolateral corrective force to the pelvis toward the paretic side during early stance phase. Three different amounts of corrective force were applied. Electromyographic (EMG) activity of the paretic leg, spatiotemporal gait parameters and pelvis lateral displacement were collected.ResultsSignificant increases in integrated EMG of hip abductor, medial hamstrings, soleus, rectus femoris, vastus medialis and tibialis anterior were observed when pelvic corrective force was applied, with pelvic corrective force at 9% of body weight inducing greater muscle activity than 3% or 6% of body weight. Pelvis lateral displacement was more symmetric with pelvic corrective force at 9% of body weight.ConclusionsApplying a mediolateral pelvic corrective force toward the paretic side may enhance muscle activity of the paretic leg and improve pelvis displacement symmetry in individuals post-stroke.SignificanceForceful weight shift to the paretic side could potentially force additional use of the paretic leg and improve the walking pattern.
from Physiology via xlomafota13 on Inoreader http://ift.tt/2uRuR8M
via IFTTT
Εγγραφή σε:
Σχόλια ανάρτησης (Atom)
Δεν υπάρχουν σχόλια:
Δημοσίευση σχολίου
Σημείωση: Μόνο ένα μέλος αυτού του ιστολογίου μπορεί να αναρτήσει σχόλιο.