Abstract
Introduction
The purpose of this study was to assess robot‐assisted suturing skills on a laparoscopic intestinal anastomosis model by using a novel computerized objective assessment system.
Methods
This study compared the suturing skills of 13 surgically naïve participants on an artificial intestinal anastomosis model that mimics real tissue. Each examinee sutured using da Vinci robot assistance under 2‐D and 3‐D visualization and with conventional laparoscopy (CL). Pressure‐measuring and image‐processing devices were employed to quantitatively evaluate suturing skills. Five unique criteria were used to evaluate the skills of participants.
Results
Suturing under 3‐D visualization (P < 0.01) and with CL (P < 0.05) were significantly faster than under 2‐D visualization. Sutures placed under 3‐D (P < 0.05) and 2‐D (P < 0.01) visualization had significantly better suture tension than those placed with CL, which did not meet acceptable values for suture tension. Sutures placed with CL had significantly better air pressure leakage than those placed under 2‐D visualization (P < 0.05), which did not meet acceptable values for air pressure leakage and wound opening area. One participants failed to achieve full‐thickness sutures with 2‐D, two participants with CL, and one participant with 3‐D.
Conclusion
Using 3‐D vision is necessary for complex maneuvering during robot‐assisted minimally invasive surgery. Our quantitative assessment system is useful for evaluating the skill acquisition of surgeon‐trainees undergoing robotic surgery training.
from Endoscopy via xlomafota13 on Inoreader https://ift.tt/2QCnMV6
via IFTTT
Δεν υπάρχουν σχόλια:
Δημοσίευση σχολίου
Σημείωση: Μόνο ένα μέλος αυτού του ιστολογίου μπορεί να αναρτήσει σχόλιο.