BACKGROUND: Plasma transfusion is commonly performed for the correction of abnormal coagulation screening tests. The goal of this investigation was to assess the relationship between the dose of plasma administered and changes in coagulation test results in a large and diverse cohort of patients with varying levels of coagulation abnormalities and comorbid disease and in a variety of clinical settings. METHODS: In this single-center historical cohort study, all plasma transfusion episodes in adult patients with abnormal coagulation screening tests were extracted between 2011 and 2015. The primary outcome was the proportion of patients attaining normal posttransfusion international normalized ratio (INR ≤1.1) with secondary outcomes including the proportion of patients attaining partial normalization of INR (INR ≤1.5) or at least 50% normalization in pretransfusion values with respect to an INR of 1.1. RESULTS: In total, 6779 unique patients received plasma with a median (quartiles) pretransfusion INR of 1.9 (1.6–2.5) and a median transfusion volume of 2 (2–3) units. The majority (85%) of transfusions occurred perioperatively, with 20% of transfusions administered prophylactically before a procedure. The median decrease in INR was 0.4 (0.2–0.8). Complete INR normalization was obtained in 12%. Reductions in INR were modest with pretransfusion INR values
from Anaesthesiology via xlomafota13 on Inoreader https://ift.tt/2E4Nnvq
via IFTTT
Εγγραφή σε:
Σχόλια ανάρτησης (Atom)
Δεν υπάρχουν σχόλια:
Δημοσίευση σχολίου
Σημείωση: Μόνο ένα μέλος αυτού του ιστολογίου μπορεί να αναρτήσει σχόλιο.