Abstract
Background
Adenoma detection rate (ADR) is a quality indicator for screening colonoscopy, but its calculation is time-consuming. Polyp detection rate (PDR) has been found to correlate with ADR; however, its use as a quality indicator has been criticized out of concern for endoscopists artificially inflating the PDR. We aim to evaluate whether active monitoring affects PDR.
Methods
In March 2015, 14 endoscopists were made aware that their personal PDRs would be tracked monthly as a quality improvement project. Endoscopists received a report of their individual monthly and cumulative PDR, departmental averages, and a benchmark PDR. Following the intervention, data were collected for consecutive patients undergoing average risk screening colonoscopy for six months. PDR, ADR, and adenoma to polyp detection ratio quotient (APDRQ) were compared to a six-month pre-intervention period.
Results
2203 patients were included in the study. There was no statistically significant difference in PDR when comparing pre- and post-intervention (44 vs. 45%, OR 1.04; 95% CI 0.77–1.36). No statistically significant difference in ADR was observed when comparing pre- and post-intervention (29 vs. 30%, OR 1.03; 95% CI 0.64–1.52). There was no statistically significant difference in APDRQ when comparing pre- and post-intervention (0.67 vs. 0.66, OR 0.99; 95% CI 0.69–1.33).
Conclusions
Monthly report cards did not result in a change in PDR or APDRQ. In some environments, PDR can be used as a surrogate marker of ADR, despite endoscopist awareness that PDR is being measured.
from Endoscopy via xlomafota13 on Inoreader http://ift.tt/2i3wz2w
via IFTTT
Δεν υπάρχουν σχόλια:
Δημοσίευση σχολίου
Σημείωση: Μόνο ένα μέλος αυτού του ιστολογίου μπορεί να αναρτήσει σχόλιο.