Intra-operative cutaneous temperature monitoring with zero-heat-flux technique (3M SpotOn) in comparison with oesophageal and arterial temperature: A prospective observational study

BACKGROUND Continuous monitoring of core temperature is essential during major surgery as a way of improving patient safety. Oesophageal probes or specific arterial catheters are invasive methods used in this setting. A new noninvasive device based on zero-heat-flux (ZHF) technique (SpotOn) seems promising but has been poorly investigated during rapid core temperature changes (RCTC). OBJECTIVE To assess the accuracy of a SpotOn sensor vs. an oesophageal probe or specific arterial catheter during a slow change in core temperature of less than 1 °C within 30 min and RCTC ≥ 1 °C within 30 min. DESIGN Prospective observational study. SETTING Operating rooms at the University Hospital of Poitiers, France. PATIENTS Fifty patients scheduled for major abdominal surgery under general anaesthesia were enrolled from June 2015 to March 2016. Data from 49 patients were finally analysed. Among these, 15 patients were treated with hyperthermic intraperitoneal chemotherapy. INTERVENTION Each patient had a ZHF sensor placed on the skin surface of the forehead (TempZHF) and an oesophageal probe (TempEso) used as a reference method. Twenty-two patients also had a thermodilution arterial catheter (TempArt) placed in the axillary artery. MAIN OUTCOME MEASURES Core temperature was continuously recorded from the three devices after induction of anaesthesia. Comparison of temperature measurements between methods was made using the Bland and Altman method during two separate periods according to the speed of core temperature changes. RESULTS Compared with TempEso, bias and limits of agreement for TempZHF were 0.1 ± 0.5 °C during slow core temperature changes periods and 0.6 ± 1.8 °C during RCTC periods (P = 0.0002). Compared with TempArt, these values were −0.1 ± 0.4 and 0.5 ± 1.7 °C, respectively (P = 0.0039). The ZHF sensor was well tolerated. CONCLUSION A SpotOn sensor using the ZHF method seems reliable for core temperature monitoring during abdominal surgery when variations in core temperature are slow rather than rapid. TRIAL REGISTRATION ClinicalTrials.gov identifier: NCT02869828. Correspondence to Matthieu Boisson, Centre Hospitalier Universitaire de Poitiers, Poitiers, France E-mail: matthieu.boisson@chu-poitiers.fr © 2018 European Society of Anaesthesiology

from Anaesthesiology via xlomafota13 on Inoreader https://ift.tt/2Kq3TL8
via IFTTT

Δεν υπάρχουν σχόλια:

Δημοσίευση σχολίου

Σημείωση: Μόνο ένα μέλος αυτού του ιστολογίου μπορεί να αναρτήσει σχόλιο.