Τετάρτη 25 Απριλίου 2018

Comparison of experimental and calculated shielding factors for modular buildings in a radioactive fallout scenario

S0265931X.gif

Publication date: September 2018
Source:Journal of Environmental Radioactivity, Volume 189
Author(s): Yvonne Hinrichsen, Robert Finck, Karl Östlund, Christopher Rääf, Kasper Grann Andersson
Experimentally and theoretically determined shielding factors for a common light construction dwelling type were obtained and compared. Sources of the gamma-emitting radionuclides 60Co and 137Cs were positioned around and on top of a modular building to represent homogeneous fallout. The modular building used was a standard prefabricated structure obtained from a commercial manufacturer. Four reference positions for the gamma radiation detectors were used inside the building. Theoretical dose rate calculations were performed using the Monte Carlo code MCNP6, and additional calculations were performed that compared the shielding factor for 137Cs and 134Cs. This work demonstrated the applicability of using MCNP6 for theoretical calculations of radioactive fallout scenarios. Furthermore, the work showed that the shielding effect for modular buildings is almost the same for 134Cs as for 137Cs.



from Radiology via xlomafota13 on Inoreader https://ift.tt/2Hp5eE9