Rekha Suthar, Osman Nawazish Salaria, Carolina De La Cuesta, Omar Viswanath
Annals of Cardiac Anaesthesia 2017 20(4):459-461
A patient presented for an elective transcatheter aortic valve replacement with temporary transvenous pacing (TVP) wires placement per protocol. On postoperative day 1, the patient remained stable, so the wires were subsequently removed, after which the patient acutely decompensated, with transthoracic echocardiography revealing pericardial effusion. Emergent pericardiocentesis was performed, and a pericardial drain was placed. Three days later, the drain was removed; again, the patient acutely decompensated, requiring another emergent pericardiocentesis. Despite the relatively benign nature of TVP wires and pericardial drains, the possibility of cardiac tamponade should be kept in mind as a potential complication when they are being removed.
from Anaesthesiology via xlomafota13 on Inoreader http://ift.tt/2kCM42A