BACKGROUND: Blood product mistransfusions occur when a process error causes transfusion of incompatible blood products. These events are known sources of negative patient outcomes. One such event demonstrated an institutional knowledge gap and an opportunity to reduce this source of transfusion errors. The focus of this study was to evaluate the application of point of care cognitive aids to bridge potentially lethal knowledge gaps in blood product to patient compatibility. METHODS: A patient-donor ABO antigen compatibility grid for red blood cells (RBC) and fresh frozen plasma (FFP) was developed for creation of a cognitive aid and a blood product safety quiz. Participants included 117 registered nurses and postgraduate medical interns who were given 2 minutes to complete the quiz for establishing institutional controls. A separate group of 111 registered nurses and interns were given the same timed quiz twice, without and then with a blood product compatibility cognitive aid. An analysis of covariance was used to evaluate without cognitive aid versus with cognitive aid quiz results while taking the specialty (nurse versus interns) and baseline score into consideration. The blood bank adopted the grid as a forcing function to be completed before release of blood products. RESULTS: The correct RBC answer percentage increased from 84.7% to 98.3% without and with cognitive aid (average improvement 13.6%, standard deviation [SD] = 18.3%, 95% confidence interval, 10.1%-17.1%, P
from Anaesthesiology via xlomafota13 on Inoreader http://ift.tt/2jMefvD