Τρίτη 20 Ιουνίου 2017

Improving Outcomes in Emergency General Surgery Patients: What Evidence Is Out There?.

No abstract available

from #ORL-AlexandrosSfakianakis via ola Kala on Inoreader http://ift.tt/2sSrqij
via IFTTT

False Low ETCO2 Measurements From Carbon Dioxide Sampling Nasal Cannula and How to Correct the Situation.

No abstract available

from Anaesthesiology via xlomafota13 on Inoreader http://ift.tt/2sRWTBb
via IFTTT

Respiratory System Mechanics During Low Versus High Positive End-Expiratory Pressure in Open Abdominal Surgery: A Substudy of PROVHILO Randomized Controlled Trial.

BACKGROUND: In the 2014 PROtective Ventilation using HIgh versus LOw positive end-expiratory pressure (PROVHILO) trial, intraoperative low tidal volume ventilation with high positive end-expiratory pressure (PEEP = 12 cm H2O) and lung recruitment maneuvers did not decrease postoperative pulmonary complications when compared to low PEEP (0-2 cm H2O) approach without recruitment breaths. However, effects of intraoperative PEEP on lung compliance remain poorly understood. We hypothesized that higher PEEP leads to a dominance of intratidal overdistension, whereas lower PEEP results in intratidal recruitment/derecruitment (R/D). To test our hypothesis, we used the volumedependent elastance index %E2, a respiratory parameter that allows for noninvasive and radiation-free assessment of dominant overdistension and intratidal R/D. We compared the incidence of intratidal R/D, linear expansion, and overdistension by means of %E2 in a subset of the PROVHILO cohort. METHODS: In 36 patients from 2 participating centers of the PROVHILO trial, we calculated respiratory system elastance (E), resistance (R), and %E2, a surrogate parameter for intratidal overdistension (%E2 > 30%) and R/D (%E2

from Anaesthesiology via xlomafota13 on Inoreader http://ift.tt/2trPm9c
via IFTTT

In Response.

No abstract available

from Anaesthesiology via xlomafota13 on Inoreader http://ift.tt/2sSxjvI
via IFTTT

A Descriptive Survey of Anesthesiology Residency Simulation Programs: How Are Programs Preparing Residents for the New American Board of Anesthesiology APPLIED Certification Examination?.

BACKGROUND: Anesthesiology residency programs may need new simulation-based programs to prepare residents for the new Objective Structured Clinical Examination (OSCE) component of the American Board of Anesthesiology (ABA) Primary Certification process. The design of such programs may require significant resources, including faculty time, expertise, and funding, as are currently needed for structured oral examination (SOE) preparation. This survey analyzed the current state of US-based anesthesiology residency programs regarding simulation-based educational programming for SOE and OSCE preparation. METHODS: An online survey was distributed to every anesthesiology residency program director in the US. The survey included 15 to 46 questions, depending on each respondent's answers. The survey queried current practices and future plans regarding resident preparation specifically for the ABA APPLIED examination, with emphasis on the OSCE. Descriptive statistics were summarized. [chi]2 and Fisher exact tests were used to test the differences in proportions across groups. Spearman rank correlation was used to examine the association between ordinal variables. RESULTS: The responding 66 programs (49%) were a representative sample of all anesthesiology residencies (N = 136) in terms of geographical location ([chi]2 P = .58). There was a low response rate from small programs that have 12 or fewer clinical anesthesia residents. Ninety-one percent (95% confidence interval [95% CI], 84% -95%) of responders agreed that it is the responsibility of the program to specifically prepare residents for primary certification, and most agreed that it is important to practice SOEs (94%; 95% CI, 88%-97%) and OSCEs (89%; 95% CI, 83%-94%). While 100% of respondents reported providing mock SOEs, only 31% (95% CI, 24%-40%) of respondents provided mock OSCE experiences. Of those without an OSCE program, 75% (95% CI, 64%-83%) reported plans to start one. The most common reasons for not having an OSCE program already in place, and the perceived challenges for implementing an OSCE program, were the same: lack of time (faculty and residents), expertise in OSCE development and assessment, and funding. CONCLUSIONS: The results provide data from residency programs for benchmarking their simulation curriculum and ABA APPLIED Examination preparation offerings. Despite agreement that residency programs should prepare residents for the ABA APPLIED Examination, many programs have yet to implement an OSCE preparation program, in part due to lack of financial resources, faculty expertise, and time. Additionally, in contrast to the SOE, the OSCE is a new format for ABA primary certification. As a result, the lack of consensus concerning preparation needs could be related to the amount information that is available regarding the examination content and assessment process. (C) 2017 International Anesthesia Research Society

from Anaesthesiology via xlomafota13 on Inoreader http://ift.tt/2ts08w3
via IFTTT

Postpartum Tubal Sterilization: Making the Case for Urgency.

The parturient who requests postpartum sterilization has given consideration to and has made decisions regarding this aspect of her medical care long before her delivery. She arrives at parturition expecting the postpartum procedure to be performed as intended. The American Congress of Obstetricians and Gynecologists has reaffirmed its opinion that postpartum sterilization is an urgent procedure, owing to the safety and superior effectiveness of tubal sterilization via minilaparotomy in the immediate postpartum period, and the adverse consequences for mothers, babies, and society when the procedure is not actualized as desired and intended. In contrast, recent practice guidelines for obstetric anesthesia address anesthetic procedural aspects and short-term safety but overlook the long-term complications and considerations associated with failure to perform postpartum sterilization as planned. In practice, procedure completion rates are strikingly low, reportedly ranging from 31% to 52%. Reasons for failure to complete abound and include inadequate resources or inavailability of necessary personnel; obstetrician reluctance due to concerns for patient regret in younger women or medical comorbidities; barriers related to provision of obstetric care in a religiously affiliated hospital, or incomplete, improperly completed, or unavailable original federal consent forms among Medicaid-insured women. The federal requirement to wait 30 days after signing informed consent, and to retain the original signed document to be physically verified at time of the procedure, serves as a significant source of health care disparity for Medicaid-dependent mothers. This article reviews these larger issues of maternal health and comprehensive maternal care to broaden the anesthesiologist's appreciation of major benefits and potential risks of postpartum sterilization, including long-term effects, to promote an evidence-based, informed, and proactive role in delivering equitable, safe, and optimal care for these patients. (C) 2017 International Anesthesia Research Society

from Anaesthesiology via xlomafota13 on Inoreader http://ift.tt/2sSjVbc
via IFTTT

Investigation of Two Prototypes of Novel Noncontact Technologies for Automated Real-Time Capture of Incremental Drug Administration Data From Syringes.

BACKGROUND: An ideal electronic anesthesia recording system would be capable of not only recording physiological data but also injectable drug doses given, including those given incrementally from one syringe, without recourse to manual data entry. We compared 2 prototype devices which wirelessly recognized individual syringes and measured changes in their plunger positions via 2 different optical noncontact means, allowing calculation of incremental drug doses given. METHODS: Both devices incorporated a radio-frequency identification reader, which wirelessly read a unique code from a radio-frequency identification tag within syringe drug labels. A custom-designed cradle oriented any inserted 1-mL to 20-mL syringe in a repeatable position. The "laser" device had a moving laser beam broken by the end of the syringe plunger. The infrared (IR) device measured time of travel of IR light from a sender to a syringe plunger and back to a receiver. Both devices could therefore determine the drug and volume administered since the previous occasion when any syringe had been used. For each syringe size of 1, 2, 5, 10, and 20 mL, 121 plunger-length measurements were made over their full range, with each machine against a reference method of water filling and weighing using a randomized de Bruijn sequence. RESULTS: For every syringe size, the laser device showed greater accuracy and precision, lower bias, and narrower limits of agreement (95% confidence intervals = bias +/- 1.96 SD) than the IR device when compared to the reference method. For all syringe sizes, the range of bias was -0.05 to 0.32 mL for the laser and -2.42 to 1.38 mL for the IR. Lin concordance correlation coefficient values for the IR versus reference methods ranged from 0.6259 to 0.9255, with the lowest coefficients seen in syringes with the shortest distance of plunger travel (2 and 5 mL), while in laser versus reference comparisons, these coefficients were similar (0.9641-0.9981) over all syringe lengths. CONCLUSIONS: Both devices measured syringe volume changes, demonstrating potential for measuring incremental drug doses, recording these, and also the time of each measurement. The IR device had no moving parts, which would be advantageous in a clinical situation. However, the current embodiment was not deemed accurate enough for clinical use, potentially remediable through improvements in hardware and software design. The laser device showed high accuracy and precision over all syringe sizes and contained volumes, and was considered potentially accurate enough for clinical use with suitable development. (C) 2017 International Anesthesia Research Society

from Anaesthesiology via xlomafota13 on Inoreader http://ift.tt/2trF0Gr
via IFTTT