Publication date: January 2019
Source: Journal of Environmental Radioactivity, Volume 196
Author(s): Abdullah E. Alali, Khaled F. Al-Shboul, Qusai Bani Yaseen, Ayah Alaroud
Abstract
A continuous passive measurement of indoor and outdoor radon R222n, concentration is carried out in the nearby residential areas surrounding a high capacity gas-fired power station. The mean value for indoor measurements was 26.5 ± 1.75 Bq/m3 that is below the worldwide indoor mean of 40 Bq/m3 and for outdoor was 39.4 ± 4.04 Bq/m3 which is higher than the worldwide average outdoor radon concentration of 10 Bq/m3. The annual estimated effective doses were found to vary from 0.54 to 1.05 mSv/y with an average value of 0.67 ± 0.04 mSv/y for indoor dose and from 0.23 to 0.57 mSv/y with an average value of 0.37 ± 0.03 mSv/y for outdoor dose with an overall mean annual effective dose of 1.03 mSv/y. Furthermore, the measured and modeled radon excess levels due to plant operation, both, show that the effect of power plant emission on atmospheric radon levels in the surrounding region is not significant.
from Radiology via xlomafota13 on Inoreader https://ift.tt/2Jd84JT