Δευτέρα 30 Απριλίου 2018

Prions, prionoids and protein misfolding disorders

Prions, prionoids and protein misfolding disorders

Prions, prionoids and protein misfolding disorders, Published online: 30 April 2018; doi:10.1038/s41576-018-0011-4

Parallels are increasingly being drawn between prion diseases and other aggregate-mediated neurodegenerative disorders. While prion diseases are a distinct subclass of protein misfolding disorders (PMDs), a better understanding of shared mechanisms is likely to benefit treatment of all PMDs.

from Genetics via xlomafota13 on Inoreader https://ift.tt/2Fu3cfZ
via IFTTT

Portable X-ray fluorescence system to measure Th and U concentrations

alertIcon.gif

Publication date: September 2018
Source:Journal of Environmental Radioactivity, Volume 189
Author(s): Marcilei A. Guazzelli da Silveira, Bruno Ribeiro Pereira, Nilberto H. Medina, Marcia A. Rizzutto
This study reports the results obtained in the analysis of waste material samples generated by the industries of phosphate fertilizers, in particular, the use of specific filters in a portable X-ray fluorescence system, a simple equipment allowing the characterization, identification and quantification of low concentrations of Th and U (ppm). The industrial byproduct is classified as a Technologically-Enhanced, Naturally-Occurring Radioactive Material - TENORM, and therefore requires monitoring for its radio-toxic activity due to the presence of radioactive thorium and uranium families. From the results obtained, it is concluded that this technique is able to determine the contents of these elements to concentrations of tens of ppm in measurements of about 300 s, and a small sample amount (∼0.1 g).



from Radiology via xlomafota13 on Inoreader https://ift.tt/2r99ZGV
via IFTTT

A zebrafish model of foxe3 deficiency demonstrates lens and eye defects with dysregulation of key genes involved in cataract formation in humans

Abstract

The Forkhead box E3 (FOXE3) gene encodes a transcription factor with a forkhead/winged helix domain that is critical for development of the lens and anterior segment of the eye. Monoallelic and biallelic deleterious sequence variants in FOXE3 cause aphakia, cataracts, sclerocornea and microphthalmia in humans. We used clustered regularly interspaced short palindromic repeats/Cas9 injections to target the foxe3 transcript in zebrafish in order to create an experimental model of loss of function for this gene. Larvae that were homozygous for an indel variant, c.296_300delTGCAG, predicting p.(Val99Alafs*2), demonstrated severe eye defects, including small or absent lenses and microphthalmia. The lenses of the homozygous foxe3 indel mutants showed more intense staining with zl-1 antibody compared to control lenses, consistent with increased lens fiber cell differentiation. Whole genome transcriptome analysis (RNA-Seq) on RNA isolated from wildtype larvae and larvae with eye defects that were putative homozygotes for the foxe3 indel variant found significant dysregulation of genes expressed in the lens and eye whose orthologues are associated with cataracts in human patients, including cryba2a, cryba1l1, mipa and hsf4. Comparative analysis of this RNA-seq data with iSyTE data identified several lens-enriched genes to be down-regulated in foxe3 indel mutants. We also noted upregulation of lgsn and crygmxl2 and downregulation of fmodb and cx43.4, genes that are expressed in the zebrafish lens, but that are not yet associated with an eye phenotype in humans. These findings demonstrate that this new zebrafish foxe3 mutant model is highly relevant to the study of the gene regulatory networks conserved in vertebrate lens and eye development.



from Genetics via xlomafota13 on Inoreader https://ift.tt/2HIMziR
via IFTTT

Prions, prionoids and protein misfolding disorders



from Genetics via xlomafota13 on Inoreader https://ift.tt/2rbGvIx
via IFTTT

Κυριακή 29 Απριλίου 2018

The emergency paediatric surgical airway: A systematic review

BACKGROUND Although an emergency surgical airway is recommended in the guidelines for a paediatric cannot intubate, cannot oxygenate (CICO), there is currently no evidence regarding the best technique for this procedure. OBJECTIVE To review the available literature on the paediatric emergency surgical airway to give recommendations for establishing a best practice for this procedure. DESIGN Systematic review: Considering the nature of the original studies, a meta-analysis was not possible. DATA SOURCES MEDLINE, EMBASE, Cochrane Central Register of Controlled Trials, Cumulative Index to Nursing and Allied Health Literature, Web of Science, Google Scholar and LILACS databases. ELIGIBILITY CRITERIA Studies addressing the paediatric emergency surgical airway and reporting the following outcomes: time to tracheal access, success rate, complications and perceived ease of use of the technique were included. Data were reported using a Strengths, Weaknesses, Opportunities and Threats analysis. Strengths and Weaknesses describe the intrinsic (dis)advantages of the techniques. The opportunities and threats describe the (dis)advantage of the techniques in the setting of a paediatric CICO scenario. RESULTS Five studies described four techniques: catheter over needle, wire-guided, cannula or scalpel technique. Mean time for placement of a definitive airway was 44 s for catheter over needle, 67.3 s for the cannula and 108.7 s for the scalpel technique. No time was reported for the wire-guided technique. Success rates were 43 (10/23), 100 (16/16), 56 (87/154) and 88% (51/58), respectively. Complication rates were 34 (3/10), 69 (11/16), 36 (55/151) and 38% (18/48), respectively. Analysis shows: catheter over needle, quick but with a high failure rate; wire-guided, high success rate but high complication rate; cannula, less complications but high failure rate; scalpel, high success rate but longer procedural time. The available data are limited and heterogeneous in terms of reported studies; thus, these results need to be interpreted with caution. CONCLUSION The absence of best practice evidence necessitates further studies to provide a clear advice on best practice management for the paediatric emergency surgical airway in the CICO scenario. Correspondence to Dr. Markus F. Stevens, Department of Anaesthesiology, Academic Medical Centre, Meibergdreef 15, Amsterdam 1105 AZ, The Netherlands E-mail: m.f.stevens@amc.uva.nl Supplemental digital content is available for this article. Direct URL citations appear in the printed text and are provided in the HTML and PDF versions of this article on the journal's Website (https://ift.tt/2ylyqmW). © 2018 European Society of Anaesthesiology

from Anaesthesiology via xlomafota13 on Inoreader https://ift.tt/2Kk9Wkd
via IFTTT

Intra-operative cutaneous temperature monitoring with zero-heat-flux technique (3M SpotOn) in comparison with oesophageal and arterial temperature: A prospective observational study

BACKGROUND Continuous monitoring of core temperature is essential during major surgery as a way of improving patient safety. Oesophageal probes or specific arterial catheters are invasive methods used in this setting. A new noninvasive device based on zero-heat-flux (ZHF) technique (SpotOn) seems promising but has been poorly investigated during rapid core temperature changes (RCTC). OBJECTIVE To assess the accuracy of a SpotOn sensor vs. an oesophageal probe or specific arterial catheter during a slow change in core temperature of less than 1 °C within 30 min and RCTC ≥ 1 °C within 30 min. DESIGN Prospective observational study. SETTING Operating rooms at the University Hospital of Poitiers, France. PATIENTS Fifty patients scheduled for major abdominal surgery under general anaesthesia were enrolled from June 2015 to March 2016. Data from 49 patients were finally analysed. Among these, 15 patients were treated with hyperthermic intraperitoneal chemotherapy. INTERVENTION Each patient had a ZHF sensor placed on the skin surface of the forehead (TempZHF) and an oesophageal probe (TempEso) used as a reference method. Twenty-two patients also had a thermodilution arterial catheter (TempArt) placed in the axillary artery. MAIN OUTCOME MEASURES Core temperature was continuously recorded from the three devices after induction of anaesthesia. Comparison of temperature measurements between methods was made using the Bland and Altman method during two separate periods according to the speed of core temperature changes. RESULTS Compared with TempEso, bias and limits of agreement for TempZHF were 0.1 ± 0.5 °C during slow core temperature changes periods and 0.6 ± 1.8 °C during RCTC periods (P = 0.0002). Compared with TempArt, these values were −0.1 ± 0.4 and 0.5 ± 1.7 °C, respectively (P = 0.0039). The ZHF sensor was well tolerated. CONCLUSION A SpotOn sensor using the ZHF method seems reliable for core temperature monitoring during abdominal surgery when variations in core temperature are slow rather than rapid. TRIAL REGISTRATION ClinicalTrials.gov identifier: NCT02869828. Correspondence to Matthieu Boisson, Centre Hospitalier Universitaire de Poitiers, Poitiers, France E-mail: matthieu.boisson@chu-poitiers.fr © 2018 European Society of Anaesthesiology

from Anaesthesiology via xlomafota13 on Inoreader https://ift.tt/2Kq3TL8
via IFTTT

W.Va. fire chief makes TIME’s top 100 influential people list

Huntington Fire Chief Jan Rader, who was recently featured in the Netflix documentary "Heroin(e)," was recognized for raising awareness about the opioid crisis

from EMS via xlomafota13 on Inoreader https://ift.tt/2r8Lz0e
via IFTTT