Τετάρτη 30 Αυγούστου 2017

Two Unique Cases of Ciprofloxacin-Associated Avulsion of Ligament and Tendon.

Ciprofloxacin is recognized to have a deleterious relationship with tendons, particularly Achilles tendinopathy, which makes up most case reports. Tendinopathy seems to occur because of induction of collagen-degrading enzymes causing damage and ischemia of the poorly vascularized regions preventing repair. The focus on the relationship of ciprofloxacin and the Achilles tendon leaves patients on fluoroquinolones with non-Achilles tendinopathy symptoms at risk of misdiagnosis. There have not been any documented instances of ligament damage with ciprofloxacin administration in the literature, although ligament and tendon compositions are similar and should have similar susceptibility. This report includes two cases, one presenting with right lateral thumb pain and a medical history of gastroenteritis treated with ciprofloxacin. Physical examination showed swelling of the right metacarpophalangeal joint and ultrasound confirmed disruption of the radial collateral ligament at insertion on first metacarpal; the second case is of a woman presenting with right hip pain in setting of chronic recurrent diverticulitis treated with ciprofloxacin. She received work-up for lumbar disc disease and spondylosis. After standard therapy with pharmacotherapy and physical therapy for radiculopathy failed, magnetic resonance imaging was performed showing near complete avulsion of the right hamstring tendons from the ischial tuberosity. Copyright (C) 2017 Wolters Kluwer Health, Inc. All rights reserved.

from Rehabilitation via xlomafota13 on Inoreader http://ift.tt/2x3z7DI
via IFTTT

Chromosome biology: Different turfs for cohesin and condensin



from Genetics via xlomafota13 on Inoreader http://ift.tt/2x3FjeU
via IFTTT

Model organisms: New tools, new insights — probing social behaviour in ants



from Genetics via xlomafota13 on Inoreader http://ift.tt/2vDxNUd
via IFTTT

Genetic engineering: Pigs without PERVs



from Genetics via xlomafota13 on Inoreader http://ift.tt/2x3A5zJ
via IFTTT

Beyond editing to writing large genomes

Advances in genome sequencing, editing and synthetic biology have enhanced the feasibility of large-scale genome engineering, termed genome writing. In this Opinion article, Chari and Church discuss the strengths and limitations of diverse strategies for genome writing, including extensively modifying existing genomes versus synthesizing genomes de novo, and they provide future visions for writing large genomes.

from Genetics via xlomafota13 on Inoreader http://ift.tt/2vDx1Xi
via IFTTT

Comparison of the laryngeal mask airway supreme and the i-gel in paralysed elderly patients: A randomised controlled trial.

BACKGROUND: The laryngeal mask airway supreme (LMA-S) and i-gel are both popular second-generation supraglottic airway devices that have been widely studied in surgical patients, but their differences in clinical performance in the elderly are not clear. OBJECTIVE: We compared the efficacy and safety of the LMA-S and i-gel in anaesthetised and paralysed elderly patients. DESIGN: A prospective, randomised and parallel study. SETTING: Single-centre trial, study period January 2014 from to October 2016. PATIENTS: One hundred and six elderly patients who underwent urological or orthopaedic surgery with an expected duration less than 2 h. INTERVENTION: Patients were allocated to either the LMA-S (n = 53) or i-gel (n = 53) group. All insertions were performed in a standardised manner according to the manufacturers' instructions. MAIN OUTCOME MEASURES: Our primary endpoint was the rate of successful insertion at the first attempt. The adequacy of positive pressure ventilation and airway sealing, fibreoptic laryngoscopy grades and stability of airway maintenance during anaesthesia were also assessed. RESULTS: Although the rate of successful insertion at the first attempt was similar between the two groups (94.3 vs. 82.7%, P = 0.072), more patients required device manipulation during insertion with the LMA-S than the i-gel (42.3 vs. 18.9%, P = 0.011). Good fibreoptic laryngoscopy grades were significantly more common with the i-gel than the LMA-S (79.3 vs. 55.8%, P = 0.042), and peak inspiratory pressures were lower in the i-gel group both immediately after insertion and at the end of surgery. Leak pressures were significantly higher in the i-gel group than the LMA-S group, both immediately after insertion and at the end of surgery (25.8 vs. 23.0, P = 0.036; and 28.1 vs. 23.7, P

from Anaesthesiology via xlomafota13 on Inoreader http://ift.tt/2x3zjm7
via IFTTT